Selects the time after which the transmitter's output will be muted if the transmitter is transmitting silence.
Selects the source for the exciter. - Internal: selects internal generator. - External: selects MPX BNC input.
Selects the time at which the output power will change from normal power to scheduled power.
Selects the time at which the output power will change from scheduled power to normal power.
Configures the Alarm pin as an Alarm (Open Collector) or as an Analog Output (0 to 5 volts) to interface with Telemetry equipment.
Selects the parameter that will be reported as an analog voltage in the alarm pin. VOut = 5/1.2*CurrentValue/NominalValue. Please refer to the manual for further information.
Selects the threshold at which the modulation level alarm will be activated. This parameter accepts values from 1000 to 100000.
Sets the threshold at which the forward power alarm will be activated. This parameter accepts values from 0 to 2000.
Sets the threshold at which the reverse power alarm is activated. This parameter accepts values from 0 to 2000.
Sets the threshold at which the PA Temperature alarm will be activated. This parameter accepts values from 0 to 150
Sets how long the error condition must occur for before an alarm is triggered. This parameter accepts values from 2 to 600.
Sets how long the error condition must have stopped for before an alarm is un-triggered. This parameter accepts values from 2 to 600.
Sets the message that will be sent when the Trigger changes to ON. Accepts text of up to 300 characters.
Sets the IP address where the log messages should be sent via UDP. Accepts IPv4 address in the form www.xxx.yyy.zzz.
Sets the port where the log messages should be sent via UDP. Disable UDP to change. This parameter accepts values from 1 to 10000.
Sets the SNMP port. Disable SNMP to change. This parameter accepts values from 1 to 1024.
An administratively-assigned name for this device. By convention, this is the device's fully-qualified domain name. Accepts text of up to 64 characters.
Trap destination 1 IP port This parameter accepts values from 1 to 1024.
Trap destination 2 IP address Accepts IPv4 address in the form www.xxx.yyy.zzz.
Sets the method used for sending emails. For simplicity, choose BW Broadcast.
Sets the email address of the sender. The unit will send e-mails through this address. Accepts text of up to 64 characters.
Sets the recipients of the emails. Multiple addresses must be separated by commas. Accepts text of up to 99 characters.
Sets the port number of the SMTP server. This parameter accepts values from 1 to 1024.
Sets the username for SMTP authentication. Must be left blank if no authentication is required. Accepts text of up to 64 characters.
Sets the password for SMTP authentication. Must be left blank if no authentication is required. Accepts text of up to 64 characters.
Sets the maximum number of emails allowed to be sent by the unit in a single day to stop spamming from intermittent errors. This parameter accepts values from 1 to 1000.
Click 'Test e-mail' to trigger a test run of the e-mail settings above. If you do not receive the e-mail within a few minutes, check the settings are correct and try again.
Sets the telnet TCP port. Disable Telnet to change. This parameter accepts values from 1 to 1024.
The physical location of this device (e.g., `TX Site 1, Rack 2'). Accepts text of up to 64 characters.
The contact details for the person who manages this device. Accepts text of up to 64 characters.